ELG-100-24DA-3Y
Request a Backorder
Submit your request and we will confirm lead time.
Submit your request and we will confirm lead time.
| Constant voltage + Constant Current mode output |
| Metal housing design with functional ground |
| Built-in active PFC function |
| Class 2 power unit |
| No load / Standby power consumption <0.5W |
| IP67 / IP65 rating for indoor or outdoor installations |
| Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off); Smart timer dimming; DALI |
| Typical lifetime > 50000 hours |
| 5 years warranty |
| AC input voltage range | 100 ~ 305VAC 142 ~ 431VDC continue, 320VAC for 24Hrs; 360VAC for 1Hr |
| AC inrush current | COLD START 60A(twidth=850μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 |
| Over voltage protection |
28 ~ 34V | 41 ~ 48V | 47 ~ 54V | 54 ~ 62V | 62 ~ 72V Shut down output voltage, re-power on to recover |
| Setup, rise, hold up time | 1000ms, 80ms/115VAC | 500ms, 100ms/230VAC |
| Withstand voltage | I/P-O/P:3.75KVAC | I/P-FG:2.0KVAC | O/P-FG:1.5KVAC |
| Working temperature | -40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) |
| Safety standards |
UL8750(type”HL”), CSA C22.2 No. 250.13-12; IEC/BS EN/EN/AS/NZS 61347-1, IEC/BS EN/EN/AS/NZS 61347-2-13 independent, BS EN/EN62384; EAC TP TC 004;BIS IS15885(for 24/24A/24B/24DA/36/36A/36B/42/42A/42ADA/42B/48/48B/54/54A/54ADA/54B only); GB19510.1, GB19510.14; IP65 or IP67;KC61347-1,KC61347-2-13 approved |
| EMC standards | EN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1 |
| Dimension (LxWxH) | 199x63x35.5mm |
| Packing | 0.85kg; 16pcs / 14.2kg / 0.72CUFT |
Your payment information is securely processed through encrypted and PCI-compliant payment systems. We do not store, collect, or have access to your credit card details. All transactions are handled by trusted payment providers to ensure your personal and financial information remains safe and protected at all times.