Quick Specs
Output Voltage
200V
Rated Current
16A
Power Rating
5000W
Waterproof
Non-waterproof
Dimensions
18.11 x 8.30 x 3.28 in
Weight
23.14 lbs

Features:

  • Multi-functional All-in-One device (AC-DC Charger + DC-AC Inverter for Load + AC Bypass for Load)
  • Built-in AC-DC high power charger up to 4520W
  • DC-AC pure sine wave output (THD<3%)
  • Instantaneous peak power of up to 10KW for AC output
  • Up to 6 units of AC output can be paralleled, expanding wattage up to 30KW (5+1 units)
  • Utilizes 3 NTN-5K unidirectional AC outputs, configurable for 3Ø4W usage
  • -30~+70℃ ultra-wide temperature range, suitable for global deployment or installation in enclosed environments
  • Built-in remote ON/OFF control
  • Protections:
    • DC input: Reverse Polarity, Low Voltage Warning and Shutdown, Over Voltage, Battery Over Discharge
    • AC output: Short Circuit, Overload, Over Temperature
  • Built-in Modbus or CAN bus communication monitoring
  • Optional intelligent controllers available for purchase:
    • CMU2E (Stand-Alone Vertical Mounting / Rail Mounting) or CMU2E-R (Rack System Installation)
  • Dimensions (length x width x height): 460 x 211 x 83.5mm
  • PCB coating for basic moisture / dust / dirt protection
  • Certifications: CB / TUV / RCM / EAC / CE / UKCA / FCC
  • Compatible with lead acid or lithium batteries
  • 5 years warranty

General Specification

DC input voltage range

(19 - 33Vdc) (38 - 66Vdc) (280 - 430Vdc)

AC output frequency

Default setting set at 50±0.1Hz

50/60Hz selectable by DIP S.W

LOW & HIGH

ALARM, SHUTDOWN, RESTART

Reverse Polarity

No damage, re-power on to recover after fault condition is removed

Over Temperature

Shut down o/p voltage, recovers automatically after temperature goes down

Output Short

Shut down the o/p voltage, and re-power it to recover

OVERLOAD (Typ.)

105 ~ 115% load for 180 sec., 115% ~ 140% load for 10 sec.

105 - 115% load for 180 sec., 115% - 150% load for 10 sec.

Protection type: Shut down o/p voltage, re-power on to recover

Remote Control

Power ON-OFF remote control by front panel dry contact connector(by RELAY), Open : Remote off ; Short: Normal work

Communication

MODBus-RTU (RS-485) / CANBus

Withstand voltage

(DC I/P - AC:3.0KVAC) (AC - FG:1.5KVAC)

Working temperature

-30 ~ +70℃(Refer to “Derating curve”)

Safety standards

CB IEC62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 approved

Dimension (LxWxH)

460x211x83.5mm

Estimate your delivery day
Enter your ZIP code to see your estimated delivery date. Transit times exclude weekends and U.S. federal holidays (observed).
Detected Area:

Payment & Security

Ach Direct Debit Amazon American Express Apple Pay Diners Club Discover Google Pay JCB Maestro Mastercard PayPal Shop Pay Union Pay USDC Visa

Your payment information is securely processed through encrypted and PCI-compliant payment systems. We do not store, collect, or have access to your credit card details. All transactions are handled by trusted payment providers to ensure your personal and financial information remains safe and protected at all times.

Same day Shipping

When you place your order before 4:00 PM ET

Send Us An Email

sales@htdelectronics.com

Chat With Our Assistant

We offer 24-hour chat support

Locations

Our main Warehouse is located in Miami, Florida