Skip to content
HTD Electronics Warehouse Open
Order in --Order now ships Today from Miami

DC-DC Converters for RV, Marine and Truck 12V/24V/48V Systems

MEAN WELL DC-DC converters to step a 24V battery down to 12V, step 12V up to 24V, or isolate sensitive loads in RVs, boats, trucks and battery systems: enclosed SD converters, DIN rail DDR modules and RSD converters for vehicles. Models shown with a Request a quote button have no stock right now; send us the model and quantity for a quote and lead time.

  • 24V โ†’ 12VSD, DDR and RSD step-down models listed below
  • IsolatedInput-output isolation listed on the SD, DDR and RSD datasheets
  • 12V ยท 24V ยท 48VInput ranges for common battery systems
24V โ†’ 12V

24V to 12V DC-DC converters: enclosed SD series

SD B-input models take a 24V battery to an isolated 12V output: 18โ€“36 VDC input on the SD-15, 19โ€“36 VDC on the SD-25 to SD-200 and 20โ€“36 VDC on the SD-350, per each datasheet. The SD-500L and SD-1000L cover 19โ€“72 VDC, so one model works on 24V and 48V systems.

SD-15B-12
SD-15B-12
15 Wยท 12 Vยท 1.25 A
Request a quote
SD-25B-12
SD-25B-12
25.2 Wยท 12 Vยท 2.1 A
Request a quote
SD-50B-12
SD-50B-12
50.4 Wยท 12 Vยท 4.2 A
Request a quote
SD-100B-12
SD-100B-12
102 Wยท 12 Vยท 8.5 A
Request a quote
SD-150B-12
SD-150B-12
150 Wยท 12 Vยท 12.5 A
Request a quote
SD-200B-12
SD-200B-12
200.4 Wยท 12 Vยท 16.7 A
Request a quote
SD-350B-12
SD-350B-12
330 Wยท 12 Vยท 27.5 A
Request a quote
SD-500L-12
SD-500L-12
480 Wยท 12 Vยท 40 A
Request a quote
Show all 9 models (1 more)

DC/DC enclosed converters โ†’

24V โ†’ 12V

24V to 12V DIN rail and vehicle converters (DDR, RSD)

DIN rail DDR converters for control boxes and battery cabinets: G-type DDR-15, DDR-30 and DDR-60 accept 9โ€“36 VDC, L-type 18โ€“75 VDC, and B-type DDR-120 and DDR-480 accept 16.8โ€“33.6 VDC. RSD converters are built for vehicle and railway batteries: RSD-30 and RSD-60 G-type take 9โ€“36 VDC and L-type 18โ€“72 VDC; the RSD-150B takes 16.8โ€“31.2 VDC. Check each datasheet for the exact range.

DDR-15G-12
DDR-15G-12
15 Wยท 12 Vยท 1.25 A
Request a quote
DDR-15L-12
DDR-15L-12
15 Wยท 12 Vยท 1.25 A
Request a quote
DDR-30G-12
DDR-30G-12
30 Wยท 12 Vยท 2.5 A
Request a quote
DDR-30L-12
DDR-30L-12
30 Wยท 12 Vยท 2.5 A
Request a quote
DDR-60G-12
DDR-60G-12
60 Wยท 12 Vยท 5 A
Request a quote
DDR-60L-12
DDR-60L-12
60 Wยท 12 Vยท 5 A
Request a quote
DDR-120B-12
DDR-120B-12
120 Wยท 12 Vยท 10 A
Request a quote
DDR-480B-12
DDR-480B-12
400.8 Wยท 12 Vยท 33.4 A
Request a quote
Show all 17 models (9 more)

View all DDR models โ†’View all RSD models โ†’DC/DC DIN rail โ†’

Step 1

Step-down vs step-up, isolated vs non-isolated

Step-down converters take a higher battery voltage (24V or 48V) to a lower one (12V). Step-up converters do the opposite, for example 12V to 24V. Isolated converters separate input and output grounds, which helps with noise and ground loops; non-isolated converters share the negative and are smaller and cheaper.

Converter rating (W) โ‰ฅ output load (A) ร— output voltage รท 0.8
Input current (A) โ‰ˆ output watts รท input voltage รท efficiency
Quick DC-DC load calculator
Total loadโ€“
Currentโ€“
Choose a supply rated at leastโ€“

Enter the output-side current (or watts). Estimate only; check the input range and efficiency in the MEAN WELL datasheet.

Also available

Also available: 12V to 24V and 24V to 24V converters

12V to 24V: SD A-type (9.2โ€“18 VDC on the SD-15 to SD-50, 9.5โ€“18 VDC on the SD-100), DDR-120A-24 (9โ€“18 VDC) and the 9โ€“36 VDC G-type DDR and RSD models. 24V to 24V: SD B-type, SD-500L and SD-1000L, DDR L- and B-type and RSD L- and B-type, with input-output isolation. Check each datasheet for the exact range.

DDR-120A-24
DDR-120A-24
100.8 Wยท 24 Vยท 4.2 A
$ 1,233.64
Shop now
SD-350B-24
SD-350B-24
350.4 Wยท 24 Vยท 14.6 A
$ 1,829.14
Shop now
SD-15A-24
SD-15A-24
15 Wยท 24 Vยท 0.62 A
Request a quote
SD-25A-24
SD-25A-24
26.4 Wยท 24 Vยท 1.1 A
Request a quote
SD-50A-24
SD-50A-24
50.4 Wยท 24 Vยท 2.1 A
Request a quote
SD-100A-24
SD-100A-24
100.8 Wยท 24 Vยท 4.2 A
Request a quote
DDR-15G-24
DDR-15G-24
15 Wยท 24 Vยท 0.63 A
Request a quote
DDR-30G-24
DDR-30G-24
30 Wยท 24 Vยท 1.25 A
Request a quote
Show all 32 models (24 more)

DC/DC enclosed converters โ†’DC/DC DIN rail โ†’

Vehicles

Wide-input and railway/vehicle models (RSD)

Vehicle and railway batteries swing well above and below their nominal voltage during cranking and charging. Wide-input RSD converters are designed for that; check the input range, operating temperature and vibration specs in the datasheet before choosing.

RSD series โ†’

AC loads

Running 120VAC loads from batteries

For microwaves, power tools and other 120VAC loads, use a true sine wave inverter instead of a DC-DC converter. MEAN WELL TS, NTS and NTU inverters run from 12V, 24V or 48V batteries.

DC/AC inverters โ†’

24V to 12V converter FAQs

How do I get 12V from a 24V truck battery?

Use a step-down DC-DC converter with a 24V-range input and 12V output, rated at your 12V load รท 0.8. Example: 15 A of 12V accessories = 180 W, so at least a 225 W converter. Do not tap 12V from one battery of a 24V pair; it unbalances the batteries.

Isolated vs non-isolated DC-DC: which do I need?

Choose isolated when the load needs its own ground reference, for radios, instruments and anything sensitive to noise or ground loops. Non-isolated is fine for simple loads that share the vehicle negative.

Can a DC-DC converter charge a battery?

Not as a rule. A standard converter has a fixed output and no charge curve, so it can overcharge or undercharge a battery. Use a battery charger, or a model whose datasheet lists a battery charging function.

What size converter for my 12V loads?

Add the current of all 12V loads that can run together, multiply by 12 and divide by 0.8. Include start-up current of pumps, fans and compressors.

Can I use them on boats (vibration, humidity)?

Yes, if the model suits the environment: check the operating temperature, humidity and vibration specs in the datasheet, and mount the converter in a dry, ventilated place away from bilge water.

Need help choosing?

Send your battery voltage, the 12V or 24V load in amps and where it will be mounted to sales@htdelectronics.com, or request a quote.